The Dose-1 is a high-precision reference class electrometer that significantly exceeds the recommendations of the IEC 60731 and the AAPM ADCL’s. It is suitable for the use with ion chambers, semiconductors and diamond probes. The DOSE-1 is ergonomically designed and intuitively easy to use. The standard DOSE-1 connects to either TNC or BNC connector types. Optionally , the DOSE-1 is compatible with TNC, BNC, M-type and BNC/banana connector types.
• Large, high contrast graphic electro luminescent display with a wide viewing angle for complete and comprehensive display of all measured values, chamber and correction factors on the main screen. • Dose, dose rate, average rate, charge, current and dose per monitor unit are all measured and displayed simultaneously in the expanded screen. • Time base for the dose rate is selectable prior to or after the measurement. The selectable units are: second, minute and hour. • The operator interface is ergonomically designed and intuitively easy to use with pop-up menus, operated by soft keys. • Storage of up to 40 detector specific data sets in a sensor library, including physical and geometrical parameters. • Built-in electrical check source as well as leakage and bias voltage testing to ensure maximum reliability and accuracy. • The DOSE-1 has a wide range power supply for automatic adoption to mains voltage worldwide. Battery operation with 4 D cells or NiCad rechargeable batteries is optionally available.
Specifications
Bias Voltage: ±600 V, programmable in steps of 1 V Sensor Connector Types
Standard Option: Triaxial TNC (threaded) or triaxial BNC (bayonet) Alternative (“Convertible Option”): PTW-M, BNC/Banana and triaxial TNC, triaxial BNC Temperature Range: 15 - 35° Relative Humidity: 10 - 80% rel humidity, max. 20 g/cm3 Power Supply (Mains): 100 - 240 V, 50/60 Hz Battery Operation (Optional): 4 D-type NCd / NMH - accumulator cells PC Interface: Bidirectional RS-232, configuration software Outer Dimensions: 6.5” H. x 10.2” W. x 10.2” D. Weight: 1.2 lbs.
Measuring Modes/Range
Charge (Dose): 40pC to 1.0C at 0.1pC resolution Current (Dose Rate): 40 pA to 1000nA at 0.1pA resolution
Measuring Quantities and Units
Electrical: charge (C), Current (A) Integrate: Gy, Sv, R, rad, rem Time Base for Rate: Second, minute, hour Interval Time Range: 1 to 9999 sec Accuracy/Repeatability: ±0.2% Leakage Current: >±10fA, typically 1fA Linearity: <±0.25% in whole range Stability: <±0.25% per year Display: Graphic electro luminescent, 160° viewing angle Zero: Automatic, within 60 sec. Memory: All setup and detector parameters stored in EEPROM Background Compensation: On/off mode with memory
|