HEAD/BODY CT PHANTOM

Item #

Description

682-461

Head/Body CT Phantom

Optional Test Inserts

682-455

Low Contrast Resolution
Measures: Low Contrast Detectability (0.3%)

682-456

TLD Holder
Measures: TLD Dose and Dose Profile (Use w/Dose Inserts)

682-457

Dose-Insert Measures: Integral Dose (14.5 mm ID;
Use with TLD Holder or Ion Chamber

682-458

Clear Resin Rod
Measures: Rod for Linearity Insert

682-459

Impulse Response
Measures: Impulse Response

682-460

Wedge
Measures: Modulation Transfer Function (MTF)

Accurate testing of all CT scanner parameters is a crucial part of a good QC program. The Head/Body CT Phantom is designed for a complete CT quality assurance program, including daily quality control tests and periodic, comprehensive QC testing to meet the requirements of the FDA.

The Head/Body Phantom consists of a head module which is a tapered disc of Solid Water® phantom material. To test a CT scanner in the head scanning mode, a ring of compact bone is mounted on the head module; for testing in the body scanning mode, a body annulus is mounted on the head module. The head module has 5 tapered cavities which accept tapered test inserts and the body annulus ring has 4 cavities, providing for a total of 9 test positions. Standard test inserts make basic QC tests possible, while the optional test inserts allow for more sophisticated tests that may be useful for physicists and engineers. These inserts are designed for maximum flexibility with a minimum of time, effort, and cost.

Reproducibility and consistency between tests can be achieved with the Head/Body CT Phantom because of its Solid Water construction. This eliminates the problems and inconvenience found with water-fillable phantoms. And because of its design, custom tests or new developments can easily be accommodated into the Head/Body CT Phantom. A carrying case in included.

Specifications

Case Size: 24” x 16” x 8.5” (61 x 40 x 22 cm)
Weight: 35 lbs (16 kg)
Item 682-461 Includes these standard test inserts:
(9) Plain: Measures Noise, CT Number, and Spatial
(1) Edge/Contrast Scales: Measures Edge/Contrast Scale Response
(1) High Contrast Resolution: Measures Spatial Resolution (0.4 to 1.5 mm at 100% Contrast
(1) Low Contrast Resolution: Measures Low Contrast Detectability (0.6%)
(1) Alignment Pin: Measures Alignment Artifact
(4) Helix: Measures (US Patent N. 4,344,183) Alignment, Slice Thickness and Phantom Position
(2) Aluminum Ramp: Measures Slice Thickness and Sensitivity Profile (26.6° Slope)
(2) Compact “Bone” Rod: Measures Beam Hardening Artifact
(6) Linearity: (2) with Acrylic (1) Teflon (1) Polyethylene (1) Polypropylene (1) Rods - Measures Linearity of CT Machine.