P.DIODES, DOSIMETERS AND ELECTROMETERS
HEADERHome

IVD 2 / rf-IVD 2 DOSE MONITORING SYSTEMS

Item #

Description

322-133

rf-IVD 2 Wireless Dose Monitoring System

322-134

Additional Detector Pod for rf-IVD 2 (4 channel pod)

322-135

IVD 2 Wired Dose Monitoring System

322-136

Additional Detector Pod of IVD 2 (4 channel pod)

322-140

Thermal Printer

322-133

INVD 2 / rf-IVD 2 Advantage
• Simple to install and easy to use.
• Automatic patient temperature compensation
• Real-time wireless available (rf-IVD 2)
Safely keep cables off the treatment floor
• Use with Control Module or PC Software
• Patient database and correction factor tools
• Accuracy and reliability proven worldwide

Hardware
• Choose four (wired) or eight (wireless) input channels
Expand to 52 inputs for TBI
• Programmable Control Module
• Use with industry standard re-usable detector options
QED - flat for easy patient placement
ISORAD - cylindrical for isotropic response

IVD 2:
• Real-time wired operation
• Four standard channels
Expandable to 52
• Standard Control Module and PC Software

rf-IVD 2 adds:
• Wireless operation
No cables of treatment floor
• Eight standard channels

Control Module:
• PC not required
• Takes up less space
Wall mountable

PC Software adds:
• Patient database
• Automatic correction factors
• Record and Verify interface
• Additional measurement options

Software
• Networkable patient database for storing results
• Programmable templates
• ‘Single Measurement’ and ‘Patient Measurement’ mode
For multiple fraction dose recording
• Expected vs measured dose difference and visual indicator
• Automatically apply selected correction factors
• Password protection
• Electronic signatures
• Record & Verify (R&V) interface links

Patient Measurement
• Start/Stop measurement buttons
• Channel results
• Measured, expected dose and percent difference
• Option to change SSD prior to measurement
• Accept or reject collected measurement
• Select patient, fraction and field

Patient Database
• Database edit toolbar
• Patient specific tests
• Measurement results per channel (up to 52)
• Correction factors applied per test

Correction Factors
• Correction factor type
• Instructions for setting up correction factor
• Currently selected correction factor

Pods
Channels:
Standard: 4 (IVD 2) 8 (rf-IVD 2)
Maximum: 52
Temperature Compensation: 
Automatic within 0.1°C (Neg. polarity only)
Repeatability: ±0.2% or ±0.1cGy
Polarity: Bipolar (negative or positive polarity detectors)
Leakage: Automatic compensation
Calibration: User calibrated
Warm-up time: < 30 seconds
Wireless frequency (MHz):
rf-IVD 2: USA 916.5, EU 433.92
IVD 2: N/A
Power: 
rf-IVD 2: Rechargeable NiMH battery (12 hr)
IVD 2: Power supply
Dimensions (cm): 7.0 x 12.0 x 3.0
Weight (kg): 0.34

Control Module
Display Range: 0 to 99.999 Gy; 0 to 9999.9 cGy; 0 to 999.9 R
Display: LCD, 2 line, 16 characters/line
Power: Medical power supply operating on 100-240 VAC, 47-63Hz mains, providing 18 VDC output
Dimensions (cm): 14.0 x 16.0 x 3.5
Weight (kg): 0.78

What is Included:
Control Module: Standard
PC Software: Standard
Number of Pods: 
IVD 2: One (four channels)
rf-IVD 2: Two (eight channels)
Wall mounted charging cradle: Standard