Accelerator Localizing Cross Tray

with Divergent Tungsten Pins - WEDGE Slot

The Accelerator Localizing Cross Trays have divergent tungsten pins 1/16” and 3/32” in diameter x 1/2” long. They are spaced 1 cm apart in four quadrants at isocenter. Every fifth pin is 3/32” diameter, which makes for easy counting. The small dots prevent any obscuring of the film viewing, yet allow easy measurements.

The acrylic graticule fits into the metal tray so the graticule won’t shift off center even if bumped.

Acrylic tray density = 1.185 g/cm3.

Information Needed To Order:
• Machine Manufacturer
• Model of Machine
• Does this machine have MLC
• Type of Coding - (optical, plug, etc...):
• Target to bottom of wedge tray slot in centimeters
• Serial Number - If applicable:
• Contact Person and Phone Number


Varian - Accelerator Localizing Cross Tray

Item #

Manufacturer

Description

Target to Bottom of Wedge Tray

713-101

Varian Type II

Wedge Slot, Coding Plug 15 or Plug 09 on Metal Tray

42.1, 49.2,
 53.0, 53.8

713-103

Varian Type II

Wedge Slot, Coding By-Wedge Slot,
Coding By-Pass on Metal Tray
on Metal Tray

 

713-120

Varian Type III

Wedge Slot, Optical Coded on Metal Tray

49.2, 53.0

713-121

Varian Type III with MLC

Wedge Slot, Optical Coded MLC on Metal Tray
Field Size: 30cm x 30cm

57.6

713-123

Varian Type III with MLC

Wedge Slot, Optical Coded MLC on Metal Tray,
Field Size: 40 cm x 40 cm

57.6

Graticules for Other Varian Machines are also Available.


Siemens - Accelerator Localizing Cross Tray

Item #

Manufacturer

Description

713-221

Siemens Mevatron

Wedge Slot with Screw Coding

713-232

Siemens Primus
with MLC or Mevatron

Wedge Slot w/Digital Coding Plug
(S2N01 or S2N18)

713-235

Siemens Mev 12

Wedge Slot

713-236

Siemens Mev 6

Wedge Slot

713-232

Various Manufacturers - Accelerator Localizing Cross Tray

Item #

Manufacturer

Description

713-300

AECL Therac 6

 

713-400

Elekta/Philips SL15, 18, 20, 25

Tray Slot

713-401

Elekta/Philips SL75-5

Tray Slot

713-403

Elekta/Philips SL-20, 75, L5

Mounted to Gantry Head

713-500

Mitsubishi

 

713-600

ATC/EMI

 

713-708

GE or CGR Saturne 20

 

713-710

GE Saturne 40, 41, 42, 43

Metal Tray with Coding Studs

713-711

GE Saturne MLC

 

713-712

GE Saturne 3

 

713-403
713-710

Localizing Cross Trays can be manufactured for any accelerator.

Radiation Products Design, Inc         www.rpdinc.com           sales@rpdinc.com