Veridose PDMQC System

Two Systems in One

Item #

Description

322-902

VeriDose PDMQC System

322-902-1

VeriDose V Electrometer ONLY

322-908

VeriDose Excel Add-in Software, 3.5” Floppy Disc

negative polarity diodes

Diodes Sold
Separately

Diode Holder and Calibration Jig

Diodes Not Included

Item #

Description

322-930

Diode Holder with Five Slots

322-932

Calibration Jig with Six Slots

Use VeriDose PDMQC as a patient dose monitor and when needed, just simply plug in the Veridose QC Module and VeriDose PDMQC is transformed into a precision linear accelerator quality control device.

VeriDose PDMQC is actually two radiation oncology products in one. It’s a linear accelerator quality control device (it measures beam constancy, which includes flatness and symmetry). It’s a five-channel patient dose monitoring system that records patient dose verification data from actual radiation measurements made on the patient during treatment. 

Accuracy:
• Measurements and updates are provided in real time, accurate to within 1% or better
• Automatically adjusts the proper offset voltage for each detector, resulting in up to ten times less drift than other products

Time-Savings:
VeriDose PDMQC stores up to 25 separate calibration sets. A calibration set can be created for up to 5 diodes at a time. As a result, the frequency of calibrations you do is significantly reduced. Setup time and error potential are also dramatically reduced, leaving more time for patient treatment.

Documentation:
• When interfaced with a standard printer, you can print:
1. Patient treatment dose reports
2. Date and time of procedure
3. Diode detector group and serial number
• In vivo measurements with VeriDose PDMQC as a patient dose monitor are reimbursable under CPT-4 Section 77331 Special  Dosimetry

Specifications

VeriDose PDMQC Electrometer
Input Circuitry: Five electrometer channels with digital zeroing and gain control; bi-polar
Rate Range: 1.0 cGy/minute to 1000 cGy/minute
Dose Range: 0.1 cGy to 1000 cGy
Sensitivity Adjustment: 0.1 nC/cGy to 10 nC/cGy
Display: 240 x 64 dot LCD; 8 lines x 40 characters, with CCF backlight
Clock: Real time clock, battery operated, USA or European format
Alarm: User-selectable level for each channel
User Controls: On-Off switch, 5-column select soft-keys for control functions, scroll-up, scroll-down, and enter key for data entry
User Setup Parameters: Stored in non-volatile, battery-backup
RAM
Computer Interface: RS-232C, 19.2 K BAUD, 8, N, 1; data format: standard decimal points or Euro-commas
Printer Interface: Parallel, selectable drivers for: LaserJet, Label printer; ASCII Format only.
Storage Temperature: 0° C to 70° C
Operating Temperature: 10° C to 30° C
Relative Humidity: 5% to 95% non-condensing
Connector: BNC-F Coax
Power: 120 VAC, 60 Hz or 230 VAC, 50 Hz to 12VDC @ 1A; AC adapter, UL, CSA, CE
Dimensions: 9” W x 8.5” D x 2.5” H (EMI shielded)
Weight: 2.5 lbs

VeriDose PDMQC Phantom Module
Detector: Five diode detectors
Energy Range: Photon: 4 MV to 25 MV
Electron: 5 MeV to 25 MeV
Sensitive Volume: 0.25 mm3
Sensitivity: 1.5 nC/cGy
Diode Polarity: Negative
Rad Damage at 10 kGy: <15%
Detector Configuration:
Flatness/Symmetry: One central axis
Four orthogonally-positioned at 8 cm off central axis in the transverse and radial dimensions off-axis detectors are positioned at 80% of field size for flatness and symmetry measurements
Energy Constancy: Detector Depth Positions: 4.5, 12.5, 20.5 cm
Interface Cable: 15 meters (50 feet)
Build-up: 1.9 cm acrylic (2.3 g/cm2)
Dimensions: 9.85” sq. x 1.5” H
Weight: 5.25 lbs

VeriDose PDMQC System Includes: Electrometer, Windows® Excel software, and Phantom Module.
Item 322-908 - Add-in software is needed for additional machines.
Note: Recommend negative polarity diodes with VeriDose  PDMQC System