The DMC 2000X measures, stores and displays deep dose equivalent Hp(10). It features a flat response over all practical X-ray and gamma energies from 20 keV to 6 MeV. The unit’s top mounted LCD clearly displays dose or dose rate for deep dose equivalent.
Features: X and gamma: 20 keV to 6 MeV Can be used in autonomous mode or integrated into a dosimetry system Tracking by area or sub-area History including localization Audible and visual alarms Self-testing (battery, detector and parameters) Remote dosimetry, extremity measurements, and can be used as an area monitor Backwards compatible with previous MGPI equipment
Applications: Operational dosimetry for commercial, research, civil and defense personnel working w/ionizing radiation sources. Operational dosimetry of medical personnel during X-rays monitoring and isotopic preparations. The Histogram enables events to be reconstructed in detail, allowing the circumstances surrounding incident situations to be analyzed. In motion reading allows dose management by sub-zone, as well as real-time location tracking of personnel, all without placing any restrictions on the dosimeter wearer.
Specifications
Measurement range: Dose: 0.1 mrem to 1000 rem (1 ľSv to 10Sv) Rate: 0.01 mrem/h to 1000rem/h (0.1 ľSv/h to 10Sv/h) Linearity: < ą 10% up to 100 rem/h (1Sv/h) < ą 25% up to 1000 rem/h (10Sv/h) Energy Response: detects from 20 keV to 6 MeV Accuracy: < ą 5% (Cs 137, 20 mrem/h, 0.2 mSv/h) Environmental: Temperature: 14OF to 122OF (-10OC to 50OC) Humidity: < 90% at 108OF (42OC) Storage: -22OF to 160OF( -30OC to 71OC) shock, vibration, and drop resistant not waterproof Dimensions: 1.9” W x 3.3 “ L x 0.7” T Weight: < 2.5 oz with battery Worn by detachable clip
|