An innovative area monitor that includes a built-in GM Gamma detector for monitoring rooms where radionuclides may be present or where devices producing radiation may be located.
The unit includes a remote alarm that is tethered to the primary alarm. The remote alarm includes a digital timer that keeps an integrated log of exposure time, and can be reset by the user. This feature can be useful for routing patient safety QA or as a stopwatch in the event of an emergency.
Specifications:
Sensitivity: Adjustable 2-100 mR/hr. User can adjust sensitivity via a small hole in the side of the unit. Trip level can be monitored by a DVM connected to a BNC jack on the top of the unit. Monitor voltage range 0.06-1.5 VDC Operating Voltage: 15VDC 300mA Internal Detector: Halogen quenched GM detector. Basic sensitivity 100 cpm/mR/hr (Cs-137) Internal Operating Voltage 600 VDC Battery Back-up: 8 AA batteries Dimensions: Primary Detector: 8.7” x 5.9” x 2.4” Remote Alarm: 7.6” x 4.5” x 2.3” Radiation Indicator: Radiation OFF- Green Indicator Light Radiation ON- Flashing Red Light (2 Hz) Counter: Range: 0-1,000,000 sec Resolution: 1 sec User Reset: YES Cable Length: 50’-100’ Wall Mounting: #6 screw, 4/unit Color: Grey
|