Veridose Solid State Diode Detectors

Item #

Description

Range

Polarity/Color

Build-up Type

Build-up (g/cm2)

322-911

Photon Diode Detector

1-4 MV

Positive/Blue

Cu

0.732

322-912

Photon Diode Detector

1-4 MV

Negative/Blue

Cu

0.732

322-913

Photon Diode Detector

5-11 MV

Positive/Yellow

Cu

1.359

322-914

Photon Diode Detector

5-11 MV

Negative/Yellow

Cu

1.359

322-915

Photon Diode Detector

12-17 MV

Positive/Red

Tu

2.606

322-916

Photon Diode Detector

12-17 MV

Negative/Red

Tu

2.606

322-917

Photon Diode Detector

18-25 MV

Positive/Green

Tu

3.574

322-918

Photon Diode Detector

18-25 MV

Negative/Green

Tu

3.574

322-919

Electron Diode Detector

5-25 MeV

Positive/Gray

 

0.284

322-920

Electron Diode Detector

5-25 MeV

Negative/Gray

 

0.284

322-928

9 Meter (30 Foot) Diode Extension Cable BNC-M to BNC-F

Coax Extension Cables for Diodes

Using the VeriDose PDMQC in conjunction with VeriDose Diode Detectors, you can verify the given dose quickly and accurately during treatment, thus avoiding potential misadministration of radiation.

VeriDose Diode Detectors are solid-state silicon-based radiation detectors that utilize a p-n junction. These rugged diodes are encased within a biocompatible polystyrene material. A low noise coaxial cable is used to connect the diode to an electrometer. When attached to an electrometer, these diodes provide enhanced sensitivity and instantaneous response time.

• Designed to provide superior response, reliability, and  performance
• Long-lifetime diodes. Tested 2 x 106 cGy in high-energy electron beam, the most damaging radiation
• Very low dose rate and temperature dependence
• Hemispherical shape improves isotropic response and reduces angular and field-size dependencies

Features
• Waterproof design with appropriate build-up for all clinical photon and electron energies
• Flat bottom permits secure, easy placement on the patient
• Color-coded for ease of identification
• Dose rate independent
• Responds to photons and electrons
• Responds to dose rates of 1.0 cGy/min to 1000 cGy/min
• Can be used on continuous (60CO) X-ray beams, pulsed (linear-accelerator) X-ray beams, and electron beams
• Optimized for use with Patient Dose Monitors and high-quality medical-grade ionization chamber electrometers
• All diodes are supplied with a non-crimp repairable cable with  BNC connector

Specifications

Photon and Electron Diode Detectors
Nominal Sensitivity: 1.5nC/cGy
Sensitivity Volume: 0.25 mm3
Output Polarity: Positive/Negative
Linearity: <.1% for dose ranges from 0.01 Gy to 10 Gy
<.1% for dose rates 3 to 5 Gy/min
Reproducibility: 0.2%
Angular Dependence: <2% ± 60° for lower energy diodes (Items 322-911 and 322-913). 
<2% ± 10°; <5% ± 60° for higher energy photon diodes and  electron diodes
Sensitivity Loss at 10 kGy: <15%
Cable Length: 3 meters
Connector: Coaxial BNC-M
Dimensions: 8 mm Æ
Weight: 42 gm